Summary of Safety and Clinical Performance

Split Stream®

SSCP Document Number: SSCP-007
Revision Number: 5
Revision Date: 5-Sep-25

Important Information

This Summary of Safety and Clinical Performance (SSCP) is intended to provide public access to an updated summary of the main aspects of the safety and clinical performance of the device. The information presented below is intended for patients or lay persons. A more extensive summary of safety and clinical performance prepared for healthcare professionals is found in the first part of this document.

The SSCP is not intended to give general advice on the treatment of a medical condition. Please contact your healthcare professional in case you have questions about your medical condition or about the use of the device in your situation. This SSCP is not intended to replace an Implant Card or the Instructions for Use to provide information on the safe use of the device.

1. Device Identification and General Information

Device Trade Name(s): Split Stream®

Manufacturer Name and Address: Medical Components, Inc. 1499 Delp Drive Harleysville, PA 19438 USA

Basic UDI-DI: 00884908249NH

Date First CE Certificate Was Issued for This Device: 2003

Device Grouping and Variants

The devices in scope of this document are all long-term hemodialysis catheter sets. The device part numbers are organized into variant categories. These devices are distributed as procedure trays. Procedure trays come in different configurations.

Variant Devices:

Variant Description Part Number(s)
14F x 24cm Split Stream 10298-824 10028-824
14F x 28cm Split Stream 10298-828 10028-828
14F x 32cm Split Stream 10298-832 10028-832
14F x 36cm Split Stream 10298-836 10028-836
14F x 40cm Split Stream 10298-840 10028-840
16F x 24cm Split Stream 10062-824
16F x 28cm Split Stream 10062-828
16F x 32cm Split Stream 10062-832
16F x 36cm Split Stream 10062-836
16F x 40cm Split Stream 10062-840
Variant Description Part Number(s)

Procedure Trays:

Configurations of Procedure Trays:
Catalog Code Part Number Description
Configurations of Procedure Trays:
Catalog Code Part Number Description
S24SE. 10298-824 14F x 24cm Split Stream® Catheter Sheathless Technique Set (Cuff 19cm From Tip)
S28SE. 10298-828 14F x 28cm Split Stream® Catheter Sheathless Technique Set (Cuff 19cm From Tip)
S32SE. 10298-832 14F x 32cm Split Stream® Catheter Sheathless Technique Set (Cuff 19cm From Tip)
S36SE. 10298-836 14F x 36cm Split Stream® Catheter Sheathless Technique Set (Cuff 19cm From Tip)
S40SE. 10298-840 14F x 40cm Split Stream® Catheter Sheathless Technique Set (Cuff 19cm From Tip)
SST24SE. 10298-824 14F x 24cm Split Stream® Catheter w/ Stylet Set (Cuff 19cm From Tip)
SST28SE. 10298-828 14F x 28cm Split Stream® Catheter w/ Stylet Set (Cuff 23cm From Tip)
SST32SE. 10298-832 14F x 32cm Split Stream® Catheter w/ Stylet Set (Cuff 27cm From Tip)
SST36SE. 10298-836 14F x 36cm Split Stream® Catheter w/ Stylet Set (Cuff 31cm From Tip)
SST40SE. 10298-840 14F x 40cm Split Stream® Catheter w/ Stylet Set (Cuff 35cm From Tip)
SST24E. 10028-824 14F x 24cm Split Stream® Catheter Set (Cuff 19cm From Tip)
SST28E. 10028-828 14F x 28cm Split Stream® Catheter Set (Cuff 23cm From Tip)
SST32E. 10028-832 14F x 32cm Split Stream® Catheter Set (Cuff 27cm From Tip)
SST36E. 10028-836 14F x 36cm Split Stream® Catheter Set (Cuff 31cm From Tip)
SST40E. 10028-840 14F x 40cm Split Stream® Catheter Set (Cuff 35cm From Tip)
SST2416E. 10062-824 16F x 24cm Split Stream® Catheter Set (Cuff 19cm From Tip)
SST2816E. 10062-828 16F x 28cm Split Stream® Catheter Set (Cuff 23cm From Tip)
SST3216E. 10062-832 16F x 32cm Split Stream® Catheter Set (Cuff 27cm From Tip)
SST3616E. 10062-836 16F x 36cm Split Stream® Catheter Set (Cuff 31cm From Tip)
SST4016E. 10062-840 16F x 40cm Split Stream® Catheter Set (Cuff 35cm From Tip)

Configurations of Procedure Trays:

Configuration Type
24cm and 28cm length Sets:
32cm, 36cm, and 40cm length Set:
Set w/ Stylets:
Sheathless Technique Set:

2. Intended Use of the Device

Intended Purpose: Split Stream® Catheters are intended for use in adult patients who do not have functional permanent vascular access or are not candidates for permanent vascular access for whom central venous vascular access for hemodialysis is deemed necessary based on the direction of a qualified, licensed physician. The catheter is intended to be used under the regular review and assessment of qualified health professionals. This catheter is for single use only.

Indication(s): Split Stream® Catheters are indicated for short-term or long-term use where vascular access is required for 14 days or more for the purpose of hemodialysis.

Intended Patient Group(s): Split Stream® Catheters are intended for use in adult patients who do not have functional permanent vascular access or are not candidates for permanent vascular access for whom central venous vascular access for hemodialysis is deemed necessary based on the direction of a qualified, licensed physician. The catheter is not intended for use in pediatric patients.

Contraindications and/or Limitations:

  • Known or suspected allergies to any of the components of the catheter or the kit.
  • This device is contraindicated for patients exhibiting severe, uncontrolled coagulopathy or thrombocytopenia.

3. Device Description

Device Image

Device Name: Split Stream® Catheter

Description of Device: The Split Stream® Catheters are long-term catheters. The catheters are double tubed. The catheters remove and return blood through two separate lines. The tubes are assembled during catheter placement. The tubes list the priming volume. A polyester cuff on the catheter tubing helps attach the catheter to the patient.

Device Image

Device Name:

Description of Device:

Materials / Substances in Contact with Patient Tissue:

The percentage ranges below are based on catheter weights. The 24cm catheter weighs 7.09 grams. The 40cm catheter weighs 11.58 grams.

14F Split Stream®
Material % Weight (w/w)
Polyurethane 56.22 - 59.41
Acetal co-polymer 15.01 - 17.33
Silicone 5.31 - 6.13
Barium sulfate 6.31 - 8.14
Stainless Steel 2.65 - 3.06
Nylon 4.30 - 4.96
Acrylonitrile Butadiene Styrene 3.52 - 4.07
Polyethylene terephthalate 1.65 - 1.91

The percentage ranges below are based on catheter weights. The 24cm catheter weighs 17.25 grams. The 40cm catheter weighs 19.92 grams.

16F Split Stream®
Material % Weight (w/w)
Polyurethane 56.46 - 59.51
Acetal co-polymer 14.93 - 17.15
Silicone 5.28 - 6.07
Barium sulfate 6.45 - 8.20
Stainless Steel 5.28 - 6.07
Nylon 4.27 - 4.91
Acrylonitrile Butadiene Styrene 3.51 - 4.03
Polyethylene terephthalate 1.65 - 1.90

Note: The device should not be used if you are allergic to the above materials.:

Note: Accessories containing stainless steel may contain up to 4% weight of the CMR substance cobalt.:

Information on Medicinal Substances in the Device: N/A

How the Device Achieves its Intended Mode of Action: Hemodialysis catheters are centrally placed access tubes. A typical hemodialysis catheter uses a thin, flexible tube. The tube has two openings. The tube goes into a large vein. The vein is usually the internal jugular vein. Blood withdraws through one lumen of the catheter. The blood flows to the dialysis machine through a separate tubing set. The blood is then processed and filtered. The blood returns to the patient through the second lumen. This device is used when dialysis must start at once. Patients may not have a functioning AV fistula or graft. Catheter hemodialysis normally happens on a short term basis. Long-term access may occur in some cases. For example, when there are problems supporting an AV fistula or graft.

Cleaning (Sterilization) Information: Contents sterile and non-pyrogenic in unopened, undamaged package. Sterilized by Ethylene Oxide.

Accessories Intended for Use in Combination with the Device:

Name of Accessory Description of Accessory
Guidewire Acts as a path for other components.
Guidewire Advancer Helps guidewire introduction.
Stylet Assist in catheter insertion.
Introducer Needle Placed into the target vein to gain access.
Tunneler Creates a pocket in between muscle and skin for catheter.
Tunneler Sleeve Helps secure the catheter to the tunneler.
Peelable Introducer Used to get central venous access.
End Cap To keep the catheter clean between treatments.
Removable Hub Provides additional catheter securement.
Dilator Used to make the opening of a vessel larger.
Scalpel A cutting device.
Syringe Helps get blood return once the needle punctures the vein.
Tegaderm Dressing that protects the catheter from contamination.

4. Risks and Warnings

Contact your healthcare professional if you believe you are experiencing side-effects related to the device or its use or if you are concerned about risks. This document does not replace a consultation with your healthcare professional if needed.

How Potential Risks Have Been Controlled or Managed

  • There have been 61,824 devices sold since January 2020. There are side effects and risks associated with the device. These include:
  • Infection
  • Bleeding
  • Catheter Removal
  • Catheter Replacement These risks are reduced to an acceptable level. The labeling describes the risks. The benefit of the device is access for hemodialysis when alternatives are not suitable. These benefits outweigh the risks.
  • Remaining Risks and Undesirable Effects

  • The Split Stream® catheter is associated with risks. These include:
  • Procedural Delays
  • Thrombosis
  • Infections
  • Perforations
  • Embolism
  • Cardiac Event
  • Dissatisfaction These risks are consistent with risks of other dialysis catheters. They are not unique to the Medcomp product. Some of the most common reactions include infection. Infection may be associated with general surgical procedure and hospitalization. Infection may not always be device-related.
  • Quantification of Residual Risks
    PMS Complaints 01 January 2016 – 31 March 2025 PMCF Events
    Units Sold: 112,258 Units Studied: 107
    Patient Residual Harm Category # of Cases Per Event # of Cases Per Event
    Allergic Reaction Not Reported. Not Reported.
    Bleeding 1 Event in 16,000 Cases. Not Reported.
    Cardiac Event Not Reported. Not Reported.
    Embolism 1 Event in 100,000 Cases. Not Reported.
    Infection Not Reported. Not Reported.
    Perforation 1 Event in 100,000 Cases. Not Reported.
    Stenosis Not Reported. Not Reported.
    Tissue Injury Not Reported. Not Reported.
    Thrombosis Not Reported. Not Reported.

    Warnings and Precautions

  • The below are warnings, precautions, or measures to be taken by patient:
  • To reduce the risk of bacteria entering the catheter, wear a mask over your nose and mouth whenever the catheter is accessed.
  • Keep the catheter dressing clean and dry. The dressing should be changed by a medical professional at each dialysis session.
  • Avoid letting the catheter or catheter site go under water. Moisture near the catheter site can potentially lead to an infection.
  • Ask the doctor to explain the signs and symptoms of catheter infection.
  • Never remove the cap at the end of the catheter. The cap and clamps of the catheter must be kept closed when not being used for dialysis.
  • Summary of Any Field Safety Correction Action (FSCA)

    There were no recalls for the device between 01 April 2024 to 31 March 2025.

    5. Summary of Clinical Evaluation and Post-Market Clinical Follow-Up

    Clinical Background of Device

    The Split Stream® catheter has been available since 2003. The CE Mark was received in 2003. US FDA clearance was in February 2003. All models included are planned for distribution in the European Union.

    Clinical Evidence for CE-Marking

    The clinical literature review found 3 articles relating to the safety and/or performance of the subject device when used as intended. These articles included approximately 179 cases. Three patient level data activities received information on 107 catheters. Findings from the clinical literature and clinical survey support the performance of the subject device. All data on the Split Stream® catheter has been evaluated. The benefits of the subject device outweigh the risks when the device is used as intended. The benefit of the device is allowing hemodialysis in patients in whom other therapies or conservative care are not desirable by the physician.

    Safety

  • There is sufficient data to prove conformity to the applicable requirements. The device is safe and performs as intended and claimed by Medcomp. The device is state of the art for allowing long-term vascular access for hemodialysis in adult patients. Medcomp has reviewed:
  • Post-Market Data
  • Medcomp Information Materials
  • Risk Management Documentation The risks are appropriately displayed and consistent with the state of the art. The risks associated with the device are acceptable when weighed against the benefits. There were 285 complaints for 61,824 units sold from 01 January 2020 to 31 March 2025. The complaint rate is 0.46%.
  • 6. Possible Therapeutic Alternatives

    When considering alternative treatments, it is recommended to contact your healthcare professional who can consider your individual situation. The Kidney Disease Outcomes Quality Initiative (KDOQI) 2019 clinical practice guidelines have been used to support the below recommendations for treatments.

    Therapy Benefits Disadvantages Key Risks
    • AV Fistula
    • Permanent solution.
    • Lower complication rate than catheter.
    • Requires time.
    • Patients must sometimes self-needle stick.
    • Stenosis
    • Thrombosis
    • Aneurysm
    • Pulmonary hypertension
    • Steal Syndrome
    • Septicemia
    • Hemodialysis Catheter
    • Useful for quick access.
    • Can be used as a bridge between therapies.
    • Not permanent.
    • Catheter dysfunction can happen.
    • Benefit may not be the same for everyone.
    • Post-procedural bleeding
    • Infection
    • Thrombosis
    • Decreased blood flow in dysfunctional catheter
    • Cardiovascular events
    • Fibrin sheath formation around catheter
    • Septicemia
    • Peritoneal Dialysis
    • Less restrictive diet than hemodialysis.
    • Does not require hospitalization.
    • Clearance of impurities is limited by flow and space.
    • Peritonitis
    • Septicemia
    • Fluid overload
    • Kidney Transplant
    • Better quality of life.
    • Lower risk of death.
    • Fewer dietary restrictions.
    • Requires a donor.
    • More risky for certain groups.
    • Patient must take medication for life.
    • Medication has side effects.
    • Thrombosis
    • Hemorrhage
    • Ureteral blockage
    • Infection
    • Organ rejection
    • Death
    • Myocardial infarction
    • Stroke
    • Comprehensive Conservative Care
    • Less imposed symptom burden.
    • Preserves life satisfaction.
    • May aggravate clinical condition.
    • Not designed to treat.
    • Treatment may not actually minimize risks associated with CKD.

    7. Suggested Profile and Training for Users

    The catheter should be inserted, manipulated, and removed by a qualified, licensed physician or other qualified health care professional under the direction of a physician. In certain circumstances, patients who may be suitable for home hemodialysis may manipulate the external connections of the catheter. Consult International Society of Hemodialysis guidelines. If home dialysis is recommended, you will undergo thorough training. The objectives of the training program are: 1) Give you information to dialyze safely at home. 2) Enable you to monitor and manage your disease. 3) Help you cope with fears and restrictions of home hemodialysis. The ideal nurse trainer-to-patient ratio is typically 1:1. A training schedule will be created. Training will be individualized to your needs.

    Acronyms

    Abbreviation Definition
    AV Arteriovenous
    CE Conformité Européenne (European Conformity)
    CKD Chronic Kidney Disease
    cm centimeter
    CMR Carcinogenic, mutagenic, reprotoxic
    dba Doing Business As
    F French (thickness of catheter)
    FDA Food and Drug Administration
    FSCA Field Safety Corrective Action
    KDOQI Kidney Disease Outcomes Quality Initiative
    PA Pennsylvania
    SSCP Summary of Safety and Clinical Performance
    USA United States of America
    w/w Weight over Weight

    Version 5.00 of Medical Components, Inc. Template QA-CL-200-1