3. Περιγραφή ιατροτεχνολογικού προϊόντος
Όνομα συσκευής:
Περιγραφή ιατροτεχνολογικού προϊόντος Medcomp® /
Jet / Nipro I-Series Peritoneal Dialysis Catheters:The I-Series
Peritoneal Dialysis Catheter is used to remove and return
dialysate fluid through single lumen tubing. The lumen inner
diameter is of circular design. The distal tip is available in two
versions: straight or coiled. The catheters are available with one
or two polyester cuffs. The polyester cuffs provide material for
tissue in-growth to stabilize the catheter. A wide radiopaque
stripe extends throughout the entire length of the catheter. A
nylon luer adaptor is used to attach the catheter to the external
PD system. The catheter is available in a variety of lengths to
accommodate patient anthropometrics, physician preference and
clinical needs.
Όνομα συσκευής: Medcomp® / Jet V-Series
Peritoneal Dialysis Catheters
Περιγραφή ιατροτεχνολογικού προϊόντος Η
οικογένεια των περιφερικά εισαγόμενων κεντρικών καθετήρων
Pro-PICC® με βαλβίδα και δυνατότητα αυτόματης έγχυσης διατίθεται
σε διάφορες διαμορφώσεις αυλού και διάφορα μεγέθη. Ο αυλός του
καθετήρα τερματίζεται σε χυτευμένο συνδετικό. Ένας εγγύς αυλός
(επέκταση) εκτείνεται από το συνδετικό και τερματίζει με μια
θηλυκή βαλβίδα ασφάλισης Luer, η οποία ελέγχει τη ροή των υγρών
για να παρέχει θεραπεία μέσω έγχυσης χωρίς σφιγκτήρα. Η θετική
πίεση στον καθετήρα (βαρύτητα, αντλία, σύριγγα) ανοίγει τη
βαλβίδα. Όταν ασκείται αρνητική πίεση (αναρρόφηση), η βαλβίδα
ανοίγει, επιτρέποντας την αναρρόφηση του αίματος σε μια σύριγγα. Ο
μέγιστος συνιστώμενος ρυθμός έγχυσης ποικίλλει ανάλογα με το
μέγεθος French του καθετήρα και είναι τυπωμένος στον καθετήρα.
Jet-PICC Η οικογένεια προϊόντων περιφερικά εισαγόμενων κεντρικών
καθετήρων Jet-PICC με δυνατότητα αυτόματης έγχυσης διατίθεται σε
διάφορες διαμορφώσεις αυλού και διάφορα μεγέθη. Ο αυλός του
καθετήρα τερματίζεται σε χυτευμένο συνδετικό. Ένας εγγύς αυλός
(επέκταση) εκτείνεται από το συνδετικό και τερματίζει με έναν
θηλυκό σύνδεσμο ασφάλισης Luer. Κάθε επέκταση επισημαίνεται με τη
διάμετρο του αυλού και διαθέτει έναν σφιγκτήρα φραγής για τον
έλεγχο της ροής του υγρού και μια ετικέτα αναγνωριστικού που
επισημαίνεται με τον μέγιστο ρυθμό αυτόματης έγχυσης. Ο μέγιστος
συνιστώμενος ρυθμός έγχυσης ποικίλλει ανάλογα με το μέγεθος French
του καθετήρα και είναι τυπωμένος στον καθετήρα. Η εξωτερική
διάμετρος του αυλού αυξάνεται σταδιακά καθώς πλησιάζει στο
συνδετικό. Ο αυλός φέρει σημάνσεις βάθους ανά εκατοστό και
αριθμητική σήμανση κάθε πέμπτο εκατοστό. PFM-PICC Η οικογένεια
προϊόντων περιφερικά εισαγόμενων κεντρικών καθετήρων PFM-PICC με
δυνατότητα αυτόματης έγχυσης διατίθεται σε διάφορες διαμορφώσεις
αυλού και διάφορα μεγέθη. Ο αυλός του καθετήρα τερματίζεται σε
χυτευμένο συνδετικό. Ένας εγγύς αυλός (επέκταση) εκτείνεται από το
συνδετικό και τερματίζει με έναν θηλυκό σύνδεσμο
Υλικά / ουσίες που έρχονται σε επαφή με τον ιστό του
ασθενούς
Τα ποσοστιαία εύρη στον παρακάτω πίνακα βασίζονται στο βάρος των
περιφερικά εισαγόμενων κεντρικών καθετήρων Pro-PICC® με δυνατότητα
αυτόματης έγχυσης μονού αυλού 3F (2,56 g) και τριπλού αυλού 6F
(7,45 g).
Περιφερικά εισαγόμενος κεντρικός καθετήρας Pro-PICC με
δυνατότητα αυτόματης έγχυσης® (χωρίς βαλβίδα)
| Υλικό |
% Βάρος (κ.β.) |
| Πολυουρεθάνη |
58,88-64,09 |
| Συμπολυμερές ακετάλης |
16,82-24,41 |
| Ακριλονιτρίλιο βουταδιένιο στυρόλιο |
8,13-10,57 |
| Θειικό βάριο |
2,82-11,80 |
Τα ποσοστιαία εύρη στον παρακάτω πίνακα βασίζονται στο βάρος των
περιφερικά εισαγόμενων κεντρικών καθετήρων Pro-PICC® με δυνατότητα
αυτόματης έγχυσης μονού αυλού 4F (3,17 g) και τριπλού αυλού 6F
(7,26 g) με βαλβίδα.
Περιφερικά εισαγόμενος κεντρικός καθετήρας Pro-PICC® με
δυνατότητα αυτόματης έγχυσης (με βαλβίδα)
| Υλικό |
% Βάρος (κ.β.) |
| Πολυουρεθάνη |
86,58-91,51 |
| Θειικό βάριο |
5,78-6,83 |
| Σιλικόνη |
2,64-6,83 |
Σημείωση:Τα εξαρτήματα που περιέχουν ανοξείδωτο ατσάλι μπορεί να
περιέχουν έως και 0,4% του βάρους της ΚΜΤ ουσίας κοβάλτιο.
Σημείωση:Σύμφωνα με τις οδηγίες χρήσης, το ιατροτεχνολογικό προϊόν
αντενδείκνυται για ασθενείς με γνωστές ή πιθανολογούμενες
αλλεργίες στα παραπάνω υλικά.
Πληροφορίες σχετικά με τις φαρμακευτικές ουσίες στο
ιατροτεχνολογικό προϊόν
Δ/Υ
Πώς η συσκευή επιτυγχάνει τον προβλεπόμενο τρόπο λειτουργίας
της
Τα εν λόγω ιατροτεχνολογικά προϊόντα χρησιμοποιούν τεχνική
Seldinger ή τροποποιημένη τεχνική Seldinger για να αποκτήσουν
πρόσβαση. Η κύρια διαφορά είναι ότι η μία τεχνική χρησιμοποιεί ένα
θηκάρι εισαγωγής και η άλλη όχι. Οι τεχνικές Seldinger για φλεβική
πρόσβαση είναι γνωστές χειρουργικές τεχνικές που χρησιμοποιούνται
για την εισαγωγή συσκευών PICC. Οι οδηγίες χρήσης κάθε καθετήρα
περιγράφονται λεπτομερώς στις Οδηγίες χρήσεως. Η εισαγωγή, ο
χειρισμός και η αφαίρεση των καθετήρων πρέπει να εκτελείται μόνο
από ειδικά πιστοποιημένο ιατρό ή άλλο καταρτισμένο μέλος του
ιατρικού προσωπικού με χρήση αυστηρά ασηπτικής τεχνικής. Μετά από
την εισαγωγή τους, πραγματοποιείται η παροχή υγρών ή η αναρρόφηση
του αίματος μέσω του καθετήρα PICC συνήθως με ένα σετ σωλήνων μιας
χρήσης ή σύριγγα. Η φροντίδα του καθετήρα περιλαμβάνει τη χρήση
διαλύματος ασφάλισης για τη διατήρηση της βατότητας του καθετήρα.
Η αφαίρεση του καθετήρα πραγματοποιείται συνήθως τραβώντας απαλά
τον καθετήρα, αλλά σε ορισμένες περιπτώσεις μπορεί να απαιτήσει
την εκτέλεση χειρουργικής επέμβασης από ιατρό εξοικειωμένο με τις
κατάλληλες τεχνικές.
Πληροφορίες αποστείρωσης Το περιεχόμενο είναι
αποστειρωμένο και μη πυρετογόνο εφόσον η συσκευασία δεν έχει
ανοιχτεί και δεν έχει υποστεί βλάβη. Αποστειρώθηκε με οξείδιο του
αιθυλενίου.
Προηγούμενες γενιές / παραλλαγές
| Όνομα προηγούμενης γενιάς |
Διαφορές από το παρόν ιατροτεχνολογικό προϊόν
|
| Δ/Υ |
Δ/Υ |
Εξαρτήματα που προορίζονται για χρήση σε συνδυασμό με το
προϊόν
| Όνομα εξαρτήματος |
Περιγραφή εξαρτήματος |
|
Επικαλυμμένο ευθύγραμμο ακροφύσιο οδηγού σύρματος 0,47 mm x
70 cm (0,018)
|
30415-018-070 |
|
0,76 mm (0,030") ΕΣΔ Προσαρμογέας με πλευρική θύρα
|
10129 |
|
Βελόνα με ακροφύσιο Echo 0,9 mm ΕΞΔ x 0,5 mm ΕΣΔ x 70 mm
(21GA)
|
30205-210 |
| Συσκευή ασφάλισης |
30824 |
| Νυστέρι |
30479 |
| Στυλεός |
30198-075 |
|
Αποσπώμενος εισαγωγέας 1,1 mm ΕΣΔ x 10 cm (3,5F)
|
10700-10-035 |
|
Αποσπώμενος εισαγωγέας 1,5 mm ΕΣΔ x 10 cm (4,5F)
|
10700-10-045 |
|
Αποσπώμενος εισαγωγέας 1,8 mm ΕΣΔ x 10 cm (5,5F)
|
10700-10-055 |
|
Αποσπώμενος εισαγωγέας 2,0 mm ΕΣΔ x 10 cm (6,5F)
|
10590-10-065 |
| Σύριγγα |
3035 |
| Μετροταινία |
3418 |
| Συνδετήρας χωρίς βελόνα |
30823 |
|
Επικαλυμμένο ευθύγραμμο ακροφύσιο οδηγού σύρματος 0,47 mm x
130 cm (0,018)
|
30415-018-13065 |
|
Ευθύγραμμο ακροφύσιο οδηγού σύρματος 0,47 mm x 45 cm (0,018)
|
30330-018 |
|
Βελόνα ασφαλείας με ακροφύσιο Echo 0,9 mm ΕΞΔ x 0,5 mm ΕΣΔ x
70 mm (21GA)
|
30318-021-007 |
|
Αποσπώμενος εισαγωγέας 1,1 mm ΕΣΔ x 7 cm (3,5F)
|
10700-07-035 |
|
Αποσπώμενος εισαγωγέας 1,5 mm ΕΣΔ x 7 cm (4,5F)
|
10700-07-045 |
|
Αποσπώμενος εισαγωγέας 1,8 mm ΕΣΔ x 7 cm (5,5F)
|
10700-07-055 |
|
Αποσπώμενος εισαγωγέας 2,0 mm ΕΣΔ x 7 cm (6,5F)
|
10590-07-065 |
Άλλες συσκευές ή προϊόντα που προορίζονται για χρήση σε
συνδυασμό με τη συσκευή:
| Όνομα συσκευής ή προϊόντος |
Περιγραφή Συσκευής ή Προϊόντος |
| N/A |
N/A |
5. Περίληψη της κλινικής αξιολόγησης και της κλινικής
παρακολούθησης μετά τη διάθεση στην αγορά (ΚΠΜΔΑ)
Περίληψη των κλινικών δεδομένων που σχετίζονται με το εξεταζόμενο
ιατροτεχνολογικό προϊόν
Ειδικοί Αριθμοί Περιστατικών (Μεικτοί Αριθμοί Περιστατικών
Κοόρτης) που Προσδιορίστηκαν και Χρησιμοποιήθηκαν για την
Αξιολόγηση Κλινικής Απόδοσης
| Οικογένεια προϊόντων |
Κλινική βιβλιογραφία |
Δεδομένα ΚΠΜΔΑ |
Σύνολο |
Απαντήσεις έρευνας χρηστών |
| Κλινική βιβλιογραφία |
467 (& 3.580 περιπτώσεις μικτής κοορτής)
|
2.030 |
2.497 (& 3.580 περιπτώσεις μικτής κοορτής)
|
37 |
Η κλινική απόδοση μετρήθηκε με τη χρήση παραμέτρων που
περιλαμβάνουν, μεταξύ άλλων, το χρόνο παραμονής, τα αποτελέσματα
της εισαγωγής του καθετήρα και τη συχνότητα ανεπιθύμητων
ενεργειών. Οι κρίσιμες κλινικές παράμετροι που εξήχθησαν από αυτές
τις μελέτες πληρούσαν τα πρότυπα που ορίζονται στις κατευθυντήριες
γραμμές αναφορικά με την τεχνολογία αιχμής. Δεν υπήρξαν
απρόβλεπτες ανεπιθύμητες ενέργειες ή άλλες υψηλές εμφανίσεις
ανεπιθύμητων ενεργειών που ανιχνεύθηκαν σε καμία από τις κλινικές
δραστηριότητες. Η επιβίωση ενός δεδομένου εμφυτεύματος είναι ένα
πολυπαραγοντικό γεγονός που εξαρτάται από πολλούς παράγοντες,
όπως: τα όρια του εμφυτεύματος, τη χειρουργική τεχνική, το επίπεδο
δυσκολίας της χειρουργικής επέμβασης, την υγεία του ασθενούς, το
επίπεδο δραστηριότητας του ασθενούς, το ιατρικό ιστορικό του
ασθενούς και άλλους παράγοντες. Στην περίπτωση του περιφερικά
εισαγόμενου κεντρικού καθετήρα Pro-PICC® με δυνατότητα αυτόματης
έγχυσης, 93 καθετήρες χρησιμοποιήθηκαν 55,07 ημέρες [95%CI:
43,98-66,18 ημέρες] σύμφωνα με την κλινική χρήση που έχει
αναφερθεί μέχρι σήμερα. Με βάση αυτές τις πληροφορίες, ο
περιφερικά εισαγόμενος κεντρικός καθετήρας Pro-PICC® δυνατότητα
αυτόματης έγχυσης έχει διάρκεια ζωής 12 μηνών. Ωστόσο, η απόφαση
για την αφαίρεση ή/και την αντικατάσταση του καθετήρα θα πρέπει να
βασίζεται στην κλινική απόδοση και ανάγκη και όχι σε οποιοδήποτε
προκαθορισμένο χρονικό σημείο.
Περίληψη κλινικών δεδομένων σχετιζόμενων με την αντίστοιχη συσκευή
(αν ισχύει)
Τα κλινικά στοιχεία από τη δημοσιευμένη βιβλιογραφία και την
κλινική παρακολούθηση μετά τη διάθεση στην αγορά (ΚΠΜΔΑ) έχουν
παραχθεί ειδικά για γνωστές και άγνωστες παραλλαγές του υπό
εξέταση ιατροτεχνολογικού προϊόντος. Η αιτιολογία ισοδυναμίας στην
επικαιροποιημένη έκθεση κλινικής αξιολόγησης θα καταδείξει ότι τα
διαθέσιμα κλινικά στοιχεία για αυτές τις παραλλαγές είναι
αντιπροσωπευτικά του εύρους των παραλλαγών του ιατροτεχνολογικού
προϊόντος στην οικογένεια προϊόντων. Δεν υπάρχουν κλινικές ή
βιολογικές διαφορές μεταξύ παραλλαγών εντός της οικογένειας
προϊόντων και οι πιθανές επιπτώσεις των τεχνικών διαφορών θα
εξορθολογιστούν στην επικαιροποιημένη έκθεση κλινικής αξιολόγησης.
Περίληψη κλινικών δεδομένων από έρευνες προ της διάθεσης στην
αγορά (αν ισχύει)
Δεν χρησιμοποιήθηκαν ιατροτεχνολογικά προϊόντα προ της διάθεσης
στην αγορά για την κλινική αξιολόγηση του ιατροτεχνολογικού
προϊόντος.
Περίληψη των κλινικών δεδομένων από άλλες πηγές:
Πηγή:Περίληψη δημοσιευμένης βιβλιογραφίας
Η βιβλιογραφική έρευνα σχετικά με την κλινική τεκμηρίωση έχει
επιστρέψει δεκαέξι δημοσιευμένα άρθρα βιβλιογραφίας που
αντιπροσωπεύουν 467 ειδικές περιπτώσεις της οικογένειας του
ιατροτεχνολογικού προϊόντος Pro-PICC®, και επιπλέον 3.580
περιπτώσεις μικτής κοορτής συμπεριλαμβανομένης της οικογένειας
ιατροτεχνολογικών προϊόντων Pro- PICC®. Τα άρθρα περιελάμβαναν
τυχαιοποιημένες προοπτικές μελέτες (Paquet et al., Pittiruti et
al., Yong et al.), προοπτικές μελέτες (Cotogni et al., Derudas et
al., Zerla et al.), αναδρομικές μελέτες (Annetta et al., Annetta
et al., Jeon et al., Kim et al., Wortley et al., Yang et al., Yeon
et al., Yu and Hong), μια υβριδική προοπτική / αναδρομική μελέτη
(Biasucci et al.) και πρακτικά συνεδρίου (Casas et al.).
Βιβλιογραφία: Annetta MG, Marche B, Dolcetti L, et al.
Ultrasound-guided cannulation of the superficial femoral vein for
central venous access. J Vasc Access. 2021 Annetta MG, Ostroff M,
Marche B, et al. Chest-to-arm tunneling: A novel technique for
medium/long term venous access devices. J Vasc Access. 2021
Biasucci, D. G., Pittiruti, M., Taddei, A., Picconi, E., Pizza,
A., Celentano, D., Conti, G. (2018). Targeting zero
catheter-related bloodstream infections in pediatric intensive
care unit: a retrospective matched case-control study. The journal
of vascular access, 19(2), 119-124. Cotogni, P., Barbero, C.,
Garrino, C., Degiorgis, C., Mussa, B., De Francesco, A., &
Pittiruti, M. (2015). Peripherally inserted central catheters in
non-hospitalized cancer patients: 5- year results of a prospective
study. Support Care Cancer, 23(2), 403-409.
doi:10.1007/s00520-014-2387-9 Cotogni P, Mussa B, Degiorgis C, De
Francesco A, Pittiruti M. Comparative Complication Rates of 854
Central Venous Access Devices for Home Parenteral Nutrition in
Cancer Patients: A Prospective Study of Over 169,000
Catheter-Days. Journal of Parenteral and Enteral Nutrition.
2021;45(4):768-76. Derudas, D., Massidda, S., Simula, M. P.,
Dessì, D., Usai, S. V., Longhitano, G., Daniela Ibba, Loredana
Aracu, Monica Atzori & La Nasa, G. (2023). Peripherally
inserted central catheter insertion and management in Hodgkin and
non-Hodgkin lymphomas: a 13-year monocentric experience. Frontiers
in Hematology, 2, 1171991. Jeon, E.-Y., Cho, Y. K., Yoon, D. Υ.,
& Hwang, J. Η. (2016). Which arm and vein are more appropriate
for single-step, non-fluoroscopic, peripherally inserted central
catheter insertion? The journal of vascular access, 17(3),
249-255. Kim, H., Cho, S. B., Park, S. E., Jo, S. H., Lim, S. G.,
Jeong, Y., JH Won, WJ Yang, HC Choi, JH Ahn & Nam, I. C.
(2024). A New Equation to Estimate Peripherally Inserted Central
Catheter Length. Medicina, 60(3), 417. Paquet, F., Boucher, L. M.,
Valenti, D., & Lindsay, R. (2017). Impact of arm selection on
the incidence of PICC complications: results of a randomized
controlled trial. J Vasc Access, 18(5), 408-414.
doi:10.5301/jva.5000738 Pittiruti, M., Emoli, A., Porta, P.,
Marche, B., DeAngelis, R., & Scoppettuolo, G. (2014). A
prospective, randomized comparison of three different types of
valved and non-valved peripherally inserted central catheters. J
Vasc Access, 15(6), 519-523. doi:10.5301/jva.5000280 Sze Yong T,
Vijayanathan AA, Chung E, Ng WL, Yaakup NA, Sulaiman N. Comparing
catheter related bloodstream infection rate between cuffed
tunnelled and non-cuffed tunnelled peripherally inserted central
catheter. J Vasc Access. 2022;23(2):225-31. Wortley, V., &
Almerol, L. A. (2020). Misplacement of piccs following
power-injected CT contrast media. British Journal of Nursing,
29(19), S4-S10. Yang WJ, Kang D, Shin JH, et al. Comparison of
different techniques for the management of venous steno-occlusive
lesions during placement of peripherally inserted central
catheter. Sci Rep. 2021;11(1) Yeon, J. W., Cho, Y. K., Kim, H. M.,
Song, M. G., Song, S.-Y., Cho, S. B., & Lee, S. Y. (2018).
Interventional management of central vein occlusion in patients
with peripherally inserted central catheter placement. Journal of
Vascular Surgery: Venous and Lymphatic Disorders, 6(5), 566-574.
Yu, B., & Hong, J. (2022). Safety and Efficacy of Peripherally
Inserted Central Catheter Placement by Surgical Intensivist-Led
Vascular Access Team. Vascular Specialist International, 38(4).
Zerla, P. A., Canelli, A., Cerne, L., Caravella, G., Gilardini,
A., De Luca, G., Venezia, R. (2017). Evaluating safety, efficacy,
and cost-effectiveness of PICC securement by subcutaneously
anchored stabilization device. The journal of vascular access,
18(3), 238-242.
• Πηγή:PMCF_Infusion_201
Το μητρώο CVAD αποκτήθηκε από την CVAD Resources, LLC στις 23
Αυγούστου 2020. Όλα τα δεδομένα που ελήφθησαν αποχαρακτηρίστηκαν,
αλλά κατά τα άλλα αντιπροσώπευαν ακριβώς αυτό που εισήγαγαν οι
κλινικοί γιατροί σε διαδοχική βάση. Η Medcomp έλαβε μόνο δεδομένα
σχετικά με ιατροτεχνολογικά προϊόντα με τον κατασκευαστή να
αναφέρεται ως «Medcomp» και όλες οι πληροφορίες περιστατικών
προέρχονταν από δύο νοσοκομεία των ΗΠΑ. Το αναγνωριστικό
νοσοκομείου 121 περιγράφεται ως «Ομάδα αγγειακής πρόσβασης σε ένα
μη κερδοσκοπικό κοινοτικό νοσοκομείο» και το αναγνωριστικό
νοσοκομείου 123 περιγράφεται ως «Ομάδα PICC (περιφερικά
εισαγόμενος κεντρικός καθετήρας) σε ακαδημαϊκό ιατρικό κέντρο». Οι
ημερομηνίες εισαγωγής του ιατροτεχνολογικού προϊόντος κυμαίνονται
από τις 6 Αυγούστου 2012 έως τις 21 Απριλίου 2015. Η αφαίρεση του
ιατροτεχνολογικού προϊόντος χρονολογείται από τις 9 Αυγούστου 2012
έως τις 7 Μαΐου 2015. Καταγράφηκαν 1.826 περιπτώσεις Pro-PICC®
συμπεριλαμβανομένων διαφόρων ιατροτεχνολογικών προϊόντων μεγέθους
French (4F, 5F και 6F) και διαμόρφωσης αυλού (μονού, διπλού,
τριπλού). Τα ακόλουθα στοιχεία διαπιστώθηκε ότι επαληθεύονται από
τα πλέον πρόσφατα μέτρα έκβασης που σχετίζονται με την ασφάλεια
και την απόδοση για τα ιατροτεχνολογικά προϊόντα Pro-PICC® της
Medcomp:
Χρόνος παραμονής - 13,5 ημέρες (95%CI: 11,8-15,2)
Επεμβατικά αποτελέσματα - 98,6% (95%CI: 98,1-99,1%)
Λοίμωξη της ροής αίματος που σχετίζεται με καθετήρα - 2,4
Επιβεβαιωμένα συμβάντα ανά 1.000 ημέρες καθετήρα Οι παραλλαγές που
περιλαμβάνονται στο σύνολο δεδομένων εμφανίζονται παρακάτω.
Παραλλαγή n Μέγεθος(η) French Pro-PICC μονού αυλού 30 4F, 5F, 6F
Pro-PICC διπλού αυλού 1.647 5F, 6F Pro-PICC τριπλού αυλού 129 6F
Pro-PICC Άγνωστο 20 5F
• Πηγή:PMCF_Infusion_211
Η έρευνα καταγραφής δεδομένων γραμμής προϊόντων έγχυσης
αποσκοπούσε στην αξιολόγηση των πληροφοριών έκβασης σχετικά με την
ασφάλεια και την απόδοση για όλες τις παραλλαγές των θυρών έγχυσης
της Medcomp, ΠΕΚΦΚ, ενδιάμεσων γραμμών και ΚΦΚ. Καταγράφηκαν 70
απαντήσεις από 17 χώρες που αντιπροσωπεύουν 471 περιπτώσεις
ιατροτεχνολογικών προϊόντων. Καταγράφηκαν 204 περιπτώσεις
Pro-PICC® συμπεριλαμβανομένων διαφόρων ιατροτεχνολογικών προϊόντων
μεγέθους French (3F, 4F, 5F και 6F), με και χωρίς βαλβίδα, και
διαμόρφωσης αυλού (μονού, διπλού, τριπλού). Τα ακόλουθα στοιχεία
διαπιστώθηκε ότι επαληθεύονται από τα πλέον πρόσφατα μέτρα έκβασης
που σχετίζονται με την ασφάλεια και την απόδοση για τα
ιατροτεχνολογικά προϊόντα Pro-PICC® της Medcomp: :
Χρόνος παραμονής - 55,07 ημέρες (95%CI: 43,98-66,18)
Επεμβατικά αποτελέσματα - 95,10% (95%CI: 94,4-95,8%)
Φλεβίτιδα - Δεν έχουν αναφερθεί συμβάντα
Διήθηση/Εξαγγείωση - Δεν έχουν αναφερθεί συμβάντα
Φλεβικός θρόμβος που σχετίζεται με τον καθετήρα - Δεν αναφέρθηκαν
συμβάντα
Λοίμωξη της ροής του αίματος που σχετίζεται με τον καθετήρα - 0,39
ανά 1.000 ημέρες χρήσης του καθετήρα (95%CI: 0-0,93)
Επιπλοκές σχετιζόμενες με την αυτόματη έγχυση - 0,43% (95%CI:
0-1,3%) Οι παραλλαγές που περιλαμβάνονται στο σύνολο δεδομένων
εμφανίζονται παρακάτω. Παραλλαγή n Μέγεθος(η) French Μήκος(-η)
Pro-PICC μονού αυλού 105 3F, 4F, 5F 55 cm, 60 cm Pro-PICC μονού
αυλού με βαλβίδα 15 5F 60 cm Pro-PICC διπλού αυλού 68 4F, 5F, 6F
55 cm, 60 cm Pro-PICC τριπλού αυλού 26 6F 60 cm
Πηγή:Διάρκεια χρήσης Έρευνα πελατών
Ένα ερωτηματολόγιο διανεμήθηκε μέσω email παγκοσμίως στους χρήστες
των Medcomp PICC και CVC από τις 10 Οκτωβρίου 2019 έως τις 16
Οκτωβρίου 2019. Το ερωτηματολόγιο ζήτησε από τους ερωτηθέντες να
προσδιορίσουν, από τη δική τους εμπειρία, τον αριθμό των προϊόντων
που χρησιμοποιούνται ετησίως, τον μέσο χρόνο παραμονής και τον
μέγιστο χρόνο παραμονής για κάθε αντίστοιχη οικογένεια
ιατροτεχνολογικών προϊόντων. Για τις πέντε οικογένειες
ιατροτεχνολογικών προϊόντων, καταγράφηκαν συνολικά 69 απαντήσεις
από 14 χώρες. Οι μέσες τιμές και το εύρος των απαντήσεων για κάθε
οικογένεια ιατροτεχνολογικών προϊόντων καταρτίστηκαν στις 16
Οκτωβρίου 2019. Συλλέχθηκαν 24 απαντήσεις σχετικά με την
οικογένεια ιατροτεχνολογικών προϊόντων Pro-PICC®. Σε περίπου 8.761
ιατροτεχνολογικά προϊόντα που χρησιμοποιούνται ετησίως, ο μέσος
χρόνος παραμονής ήταν 116 ημέρες (Εύρος: 14-365 ημέρες), και ο
μέσος μέγιστος χρόνος παραμονής ήταν 360 ημέρες (Εύρος: 60-2.555
ημέρες).
• Πηγή:PMCF_Medcomp_211
Η έρευνα χρηστών της Medcomp έλαβε απαντήσεις από υγειονομικό
προσωπικό που είναι εξοικειωμένο με τη γκάμα προϊόντων της
Medcomp. 13 ερωτηθέντες απάντησαν ότι οι ίδιοι ή η εγκατάστασή
τους έχουν χρησιμοποιήσει Medcomp PICC, με 13 από αυτούς τους
ερωτηθέντες να χρησιμοποιούν το ιατροτεχνολογικό προϊόν Pro-PICC®.
Δεν παρατηρήθηκαν διαφορές στις γνώμες των χρηστών για τις
συσκευές PICC αναφορικά με τα πλέον πρόσφατα μέτρα έκβασης που
σχετίζονται με την ασφάλεια και την απόδοση ή μεταξύ των τύπων
ιατροτεχνολογικών προϊόντων που σχετίζονται με την ασφάλεια ή την
απόδοση. Τα ακόλουθα σημεία δεδομένων καταγράφηκαν από χρήστες
PICC της Medcomp (n=13):
(Μέση απόκριση κλίμακας Likert) Οι καθετήρες λειτουργούν όπως
προβλέπεται - 4,7 / 5
(Μέση απάντηση βάσει κλίμακας Likert) Η συσκευασία επιτρέπει την
άσηπτη παρουσίαση - 4,9 / 5
(Μέση απόκριση Κλίμακας Likert) Το όφελος υπερτερεί του κινδύνου -
4,6 / 5
Χρόνος παραμονής (n=11) - 58,1 ημέρες (95%CI: 15,5-100,8) Τα
ακόλουθα σημεία δεδομένων καταγράφηκαν από χρήστες PICC ® της
Medcomp (n=11):
(Μέση απόκριση κλίμακας Likert) Οι καθετήρες λειτουργούν όπως
προβλέπεται - 4,7 / 5
(Μέση απάντηση βάσει κλίμακας Likert) Η συσκευασία επιτρέπει την
άσηπτη παρουσίαση - 4,9 / 5
(Μέση απόκριση Κλίμακας Likert) Το όφελος υπερτερεί του κινδύνου -
4,7 / 5
Χρόνος παραμονής (n=8) - 66 ημέρες (95%CI: 3,7-128,3) Οι ακόλουθες
επιπλοκές αναφέρθηκαν για συσκευές Pro-PICC®:
Θέματα τοποθέτησης (Δεν υπάρχουν σχόλια σχετικά με τη συχνότητα)
DVT (εν τω βάθει φλεβική θρόμβωση) (Δεν υπάρχουν σχόλια σχετικά με
τη συχνότητα)
Μόλυνση (Δεν υπάρχουν σχόλια σχετικά με τη συχνότητα)
Θρόμβωση (δεν υπάρχουν σχόλια σχετικά με τη συχνότητα)
Απόφραξη (Δεν υπάρχουν σχόλια σχετικά με τη συχνότητα)
Γενική περίληψη κλινικής ασφάλειας και απόδοσης
Μετά την εξέταση των δεδομένων σε όλες τις πηγές, είναι δυνατόν να
συναχθεί το συμπέρασμα ότι τα οφέλη του εν λόγω ιατροτεχνολογικού
προϊόντος, το οποίο διευκολύνει την αναρρόφηση του αίματος για
εργαστηριακές εξετάσεις, την παροχή υγρών και φαρμάκων για
θεραπείες συμπεριλαμβανομένης της χημειοθεραπείας και την αυτόματη
έγχυση σκιαγραφικών μέσων για εξετάσεις CT σε ασθενείς στους
οποίους βραχυπρόθεσμη ή μακροπρόθεσμη περιφερική πρόσβαση στο
κεντρικό φλεβικό σύστημα χωρίς να απαιτούνται συχνά τρυπήματα με
βελόνες που κρίνονται απαραίτητα με βάση την καθοδήγηση ενός
καταρτισμένου, πιστοποιημένου ιατρού, υπερτερούν των συνολικών και
μεμονωμένων κινδύνων όταν το ιατροτεχνολογικό προϊόν
χρησιμοποιείται όπως προβλέπεται από τον κατασκευαστή. Η
γνωμάτευση του κατασκευαστή και του αξιολογητή του κλινικού
εμπειρογνώμονα είναι ότι οι δραστηριότητες, τόσο οι ολοκληρωμένες
όσο και οι εξελισσόμενες, επαρκούν για την υποστήριξη της
ασφάλειας, της αποδοτικότητας και του αποδεκτού προφίλ
οφέλους/κινδύνου των εν λόγω ιατροτεχνολογικών προϊόντων.
| Έκβαση |
Κριτήρια αποδοχής οφέλους/κινδύνου |
Επιθυμητή τάση |
Κλινική βιβλιογραφία(Εξεταζόμενο προϊόν)
|
Δεδομένα ΚΠΜΔΑ (Εξεταζόμενο προϊόν) |
| Απόδοση |
| Χρόνος παραμονής |
Μεγαλύτερος από 6,27 ημέρες |
+
|
15-575 ημέρες (Περίληψη δημοσιευμένης βιβλιογραφίας)
|
55,07 ημέρες (PMCF_Infusion_211) 13,5 ημέρες
(PMCF_Infusion_201) 116 ημέρες (Διάρκεια χρήσης Έρευνα
πελατών) 66 ημέρες (PMCF_Medcomp_211) Απόκριση κλίμακας
Likert 4,7/5 (Ενότητα 6.5.8)**
|
| Επεμβατικά αποτελέσματα |
Υψηλότερα από 43% (πλάι της κλίνης) / 90% (Επεμβατική
Ακτινολογία)
|
+
|
46,3-53,7% ημέρες από το πλάι της κλίνης (Περίληψη
δημοσιευμένης βιβλιογραφίας) 99,7-100% (Περίληψη
δημοσιευμένης βιβλιογραφίας)
|
95,10% (PMCF_Infusion_211) 98,6% (PMCF_Infusion_201)
Απόκριση κλίμακας Likert 4,7/5 (PMCF_Medcomp_211)**
|
| Ασφάλεια |
| Φλεβίτιδα |
Λιγότεροι από 2,4% καθετήρες με αναφερόμενα περιστατικά
φλεβίτιδας
|
-
|
ΔΔ*
|
Δεν αναφέρθηκε καμία (PMCF_Infusion_211) Απόκριση κλίμακας
Likert 4,6/5 (PMCF_Medcomp_211)**
|
| Διήθηση/ Εξαγγείωση |
Λιγότεροι από 7% καθετήρες με αναφερόμενα περιστατικά
διήθησης ή εξαγγείωσης
|
-
|
0,6-7% (Περίληψη δημοσιευμένης βιβλιογραφίας)
|
Δεν αναφέρθηκε καμία (PMCF_Infusion_211) Απόκριση κλίμακας
Likert 4,7/5 (PMCF_Medcomp_211)**
|
|
Φλεβική θρόμβωση συνδεόμενη με τον καθετήρα (CAVT)
|
Λιγότερα από 5,4 περιστατικά CAVT ανά 1.000 ημέρες χρήσης
του καθετήρα
|
-
|
0-1,0 ανά 1.000 ημέρες χρήσης καθετήρα (Περίληψη
δημοσιευμένης βιβλιογραφίας)
|
Δεν αναφέρθηκε καμία (PMCF_Infusion_211) Απόκριση κλίμακας
Likert 4,5/5 (PMCF_Medcomp_211)**
|
|
Λοίμωξη της ροής του αίματος που σχετίζεται με τον καθετήρα
κεντρικής φλέβας (CLABSI) / Λοίμωξη της ροής του αίματος που
σχετίζεται με τον καθετήρα (CRBSI)
|
Λιγότερα από 5,7 περιστατικά CRBSI ανά 1.000 ημέρες χρήσης
του καθετήρα
|
-
|
0-2,73 ανά 1.000 ημέρες χρήσης καθετήρα (Περίληψη
δημοσιευμένης βιβλιογραφίας)
|
0,39 ανά 1.000 ημέρες χρήσης του καθετήρα (PMCF_LTHD_211)
2,4 ανά 1.000 ημέρες χρήσης του καθετήρα (PMCF_LTHD_201)
Απόκριση κλίμακας Likert 4,7/5 (PMCF_Medcomp_211)**
|
|
Επιπλοκές που σχετίζονται με την αυτόματη έγχυση
|
Λιγότεροι από 1,8% καθετήρες με αναφερόμενα περιστατικά
ρήξης λόγω της έγχυσης σκιαγραφικού μέσου Λιγότεροι από
15,4% καθετήρες με αναφερόμενα περιστατικά μετατόπισης λόγω
της έγχυσης σκιαγραφικού μέσου
|
-
|
0,6-0,7% (Περίληψη δημοσιευμένης βιβλιογραφίας)
|
0,43% (PMCF_Infusion_211) Απόκριση κλίμακας Likert 4,7/
(PMCF_Medcomp_211)**
|
*Το ΔΔ υποδηλώνει ότι δεν υπάρχουν δεδομένα για την παράμετρο των
κλινικών δεδομένων.:
***H PMCF_Medcomp_211 ρώτησε τους ερωτηθέντες, εάν συμφώνησαν σε
κλίμακα 1-5, ότι η εμπειρία τους σε σχέση με κάθε έκβαση ήταν η
ίδια ή καλύτερη από τα κριτήρια αποδοχής οφέλους/κινδύνου.:
| Έκβαση |
Κριτήρια αποδοχής οφέλους/κινδύνου |
Επιθυμητή τάση |
Κλινική βιβλιογραφία(Εξεταζόμενο προϊόν)
|
Δεδομένα ΚΠΜΔΑ (Εξεταζόμενο προϊόν) |
| Απόδοση |
| Ασφάλεια |
Συνεχής ή προγραμματισμένη κλινική παρακολούθηση μετά τη διάθεση
στην αγορά (ΚΠΜΔΑ)
| Δραστηριότητα |
Περιγραφή |
Αναφορά |
Χρονοδιάγραμμα |
|
Πολυκεντρική σειρά περιστατικών σε επίπεδο ασθενούς
|
Καταγραφή πρόσθετων κλινικών δεδομένων για το
ιατροτεχνολογικό προϊόν
|
PMCF_PICC_231 |
4ο τρίμηνο 2025 |
|
Αναζήτηση στην εγκεκριμένη βιβλιογραφία
|
Εντοπισμός κινδύνων και τάσεων με τη χρήση παρόμοιων
ιατροτεχνολογικών προϊόντων
|
Έγχυση SAP |
2ο τρίμηνο 2025 |
|
Αναζήτηση βιβλιογραφίας κλινικής τεκμηρίωσης
|
Εντοπισμός κινδύνων και τάσεων με τη χρήση του
ιατροτεχνολογικού προϊόντος
|
Έγχυση LRP |
2ο τρίμηνο 2025 |
|
Αναζήτηση στη συνολική βάση δεδομένων κλινικών δοκιμών
|
Προσδιορισμός συνεχιζόμενων κλινικών δοκιμών που αφορούν
καθετήρες Medcomp®
|
Δ/Υ |
3ο τρίμηνο 2025 |
|
Ερωτήματα δεδομένων Truveta και αναδρομική ανάλυση
|
Καταγραφή πρόσθετων κλινικών δεδομένων σχετικά με το
ιατροτεχνολογικό προϊόν και τα προϊόντα σύγκρισης
|
TBD |
4ο τρίμηνο 2025 |
Δεν έχουν εντοπιστεί αναδυόμενοι κίνδυνοι, επιπλοκές ή
απροσδόκητες αστοχίες του ιατροτεχνολογικού προϊόντος από τις
δραστηριότητες της ΚΠΜΔΑ.